Microwave Lab Kit VX-2005
Product Brochure
Following experiments can be performed using this training kits.
- To study Magic Tee, Directional Couplers, Isolators & Circulators.
- To study the Characteristics of detector diode.
- To study Attenuation measurement.
- To study the return loss measurement.
For More details please download the pdf.
Microwave Lab Kit
Product Brochure
1. To measure dielectric constant of Solids.
2. To measure dielectric constant of Liquids.
3. To measure Phase Shift.
4. To measure 'Q' of a Cavity
1. Klystron Power Supply | KP-151 | 1 No. | ||
2. Klystron Mount | X-2051 | 1 " | ||
3. Klystron Tube | 2K25 or K27 | 1 " | ||
4. Isolator | X-6021 |
| ||
5. Frequency Meter, Direct Reading Type | X-4155 | 1" | ||
6. Variable Attenuator | X-5020 | 1 " | ||
7. Slotted Section | X-6051 | 1 " | ||
8. Tunable Probe | X-6055 | 1 " | ||
9. Detector Mount | X-4051 | 1 " | ||
10. Solid Dielectric cell | X-930 | 1 " | ||
11. Liquid Dielectric cell | X-910 | 1 | ||
12. VSWR Meter, Solid State | VS-411 | 1 " | ||
13. Waveguide Stands | X-5035 | 4 " | ||
14. Waveguide Cavity | X-211 | l " | ||
15. BNCto BNC Cable | C-101 | 1 " | ||
16. Cooling Fan | - | 1 " | ||
1 7. Precision Movable Short | X-4181 | 1 " | ||
18. Waveguide Phase Shifter | X-9180 | 1 " | ||
19. Solid Dielectric of Teflon, Nylon, Ebonite, Perspex & Wax in 10, 20, 30 MM Lengths each |
| 1 Set |
For More Details Please download the PDF.
Additional Information:
- Item Code: VX-2004
Microwave Lab Kit
Product Brochure
Minimum Order Quantity | 1 Number |
Usage/Application | Laboratory |
Brand | VIDYUT |
Country of Origin | Made in India |
Following experiments can be performed using this training kits.
- To study Magic Tee, Directional Couplers, Isolators & Circulators
- To study the Characteristics of detector diode.
- To study Attenuation measurement.
- To Study the return loss measurement.
- To study the Characteristics of Gunn Diode.
- To study Frequency, Guide Wavelength & free Space Wavelength.
- To measure the SWR & Reflection Coefficient.
- To measure Impedence of a load.
- To study the Characteristics of Reflex Klystron.
Compact Microwave Labkit VX-2010 Components & Instruments:
1. Klystron Power Supply | KP-151 | 1 No. |
2. Klystron Mount | X-2051 | 1 " |
3. Klystron Tube | 2K25 or K27 | 1" |
4. Isolator | X-6021 | 1 " |
5. Frequency Meter, Direct Reading Type | X-4155 | " |
6. Variable Attenuator | X-5020 | 1 " |
7. Fixed Attenuator 3,6,10 db | X-5000 | 3 " |
8. Detector Mount | X-4051 | 1 " |
9. Movable Short | X-4081 | 1 " |
10. Slotted Section | X-6051 | 1 " |
11. Tunable Probe | X-6055 | 1 " |
12. VSWR Meter, Solid State | X-41 1 | 1 " |
Additional Information:
- Item Code: VX-2010
Compact Microwave Labkit Type Vx-2001
1 | Klystron Power Supply | KP-151 | 1 | No. |
2 | Klystron Mount | X-2051 | 1 | " |
3 | Klystron Tube | 2K25 or K27 | 1 | " |
4 | Isolator | X-602I | 1 | " |
5 | Frequency Meter, | |||
Direct Reading Type | X-4155 | 1 | " | |
6 | Variable Attenuator | X-5020 | 1 | " |
7 | Slotted Section | X-6051 | 1 | " |
8 | Tunable Probe | X-6055 | 1 | " |
9 | Detector Mount | X-4051 | 1 | " |
10 | .Movable Short | X-4081 | 1 | " |
11 | Matched Termination | X-4000 | 1 | " |
12 | VSWR Meter, Solid State | VS-411 | 1 | “ |
13 | Waveguide Stands | X-5035 | 4 | " |
14 | Slide Screw Tuner | X-4041 | 1 | " |
15 | Cooling Fan | – | 1 | " |
16 | BNC to BNC Cable | C-101 | 1 | " |
17 | BNC to Open Cable | C-102 | 1 | " |
18 | Fixed Short | UG-39/U | 1 | “ |
Compact Microwave Labkit Type Vx-2003M
Usage/Application | Laboratory |
Brand | VIDYUT |
Country of Origin | Made in India |
1 | Klystron Power Supply | KP-151 | 01 No. |
2 | Klystron Mount | X-2051 | 01 No. |
3 | Klystron Tube | 2K25 or K27 | 01 No. |
4 | Isolator | X-6021 | 01 No. |
5 | Frequency Meter, Direct Reading Type | X-4155 | 01 No. |
6 | Variable Attenuator | X-5020 | 01 No. |
7 | Microprocessor based Turn Table with Computer Interface for Polar pattern measurement | X-961 | 01 No. |
8 | Pyramidal Horn Antenna | X-5041 | 02 No. |
9 | E-Plane Bend | X-7071 | 02 No. |
10 | Detector Mount | X-4051 | 01 No. |
11 | VSWR Meter, Solid State | VS-411 | 01 No. |
Microwave Lab Kit
Following Experiments can be performed using this training kits.
- To study the Characteristics of Reflex Klystron.
- To study Frequency, Guide Wavelength & free Space Wavelength.
- To measure the SWR & Reflection Coefficient.
- To measure Impedence of a load.
- This is the basic Microwave test bench using klystron Source.
Compact microwave training kits VX-2001 consists of the following Components & Instruments :-
1. Klystron Power Supply | KP-151 | 1 No. |
2. Klystron Mount | X-2051 | 1 " |
3. Klystron Tube | 2K25 or K27 | 1 " |
4. Isolator | X-6021 | 1 " |
5. Frequency Meter, Direct Reading Type | X-4155 | 1 " |
6. Variable Attenuator | X-5020 | 1 " |
7. Slotted Section | X-6051 | 1 " |
8. Tunable Probe | X-6055 | 1 " |
9. Detector Mount | X-4051 | 1 " |
1 0. Movable Short | X-4081 | 1 " |
1 1. Matched Termination | X-4000 | 1 " |
12.VSWR Meter, Solid State | VS-411 | 1 " |
1 3. Waveguide Stands | X-5035 | 4 " |
1 4. Slide Screw Tuner | X-4041 | l " |
1 5. Cooling Fan | - | 1 " |
16. BNCto BNC Cable | C-101 | l " |
1 7. BNC to Open Cable | C-102 | 1 " |
18. Fixed Short | UG-39/U | l " |
Microwave Lab Kit
Experiments
To prove Bragg's Law using Microwave Diffraction Spectrometer
Microwave radiations are mono-chromatic, Plane Polarised and Coherent and they behave like waves. Many laboratory experiments in optics can be performed easily with simple microwave equipments, Reflection, Refraction and polarization including to prove Bragg's Law can be performed with this microwave Diffraction Spectrometer.
It consists of a Goniometer with one stationary and other rotatable arms. Each of these arms has to adjustable stands. These stands holds the transmitting horn on one end and the receiver horn on the other.
The Polyfoam containing the steel balls structure is kept in the center. A 0-360° found scale with a pointers is provided to read the position of rotatable arm.
VX-2007 Compact Microwave Labkit consists of the following Components and Instruments :
1. Klystron Power Supply | KP-151 | 1 No. |
2. Klystron Mount | X-2051 | 1 " |
3. Klystron Tube | 2K25 or K27 | 1 " |
4. Variable Attenuator | X-5020 | 1 " |
5. Pyramidal Waveguide Horn | X-5041 | 2 " |
6. Detector Mount | X- 4051 | 1 " |
7. Mechanical Turn Table with crystal Structure i.e. Diffraction Spectrometer | X-851 | 1" |
8. Waveguide Stands | X-5035 | 2 " |
9. Cooling Fan | .... | 1 " |
10. Direct Reading Frequency Meter | X-4155 | 1 " |
1 1. Isolator | X-6021 | 1 " |
12. Coaxial to Waveguide Adapter | X-7061 | 1 " |
13. Coaxial Cable N to N | C-105 | 1 " |
14. VSWR Meter | VS-411 | 1 " |
Microwave Lab Kit
Experiments:
To Study the Faraday Rotation Effects and its properties.
VX-2006 microwave training kits consists of the following Parts and Instruments :-
1. Klystron Power Supply | KP-151 | 1 No |
2. Klystron Mount | X-2051 | 1 " |
3. Klystron Tube | 2K25orK27 | 1 " |
4. Isolator | X-6021 | 1 " |
5. Frequency Meter, Direct Reading Type | X-4155 | 1 " |
6. Variable Attenuator | X-5020 | 1 " |
7. Faraday Rotation Setup consist of following components :- |
|
|
a) Circular to Waveguide Transition | X-9051 | 2 " |
b) Round Waveguide with Magnetic Coil | .... | 1 " |
c) DC Power Supply | … | 1 " |
d) Ferrite Fitted inside the round Waveguide | .... | 1 " |
f) Round Waveguide Stands | WC-281 | 2 " |
g) Rotary Joint, 1- Type | X-8181(l) | 1 " |
8. Detector Mount | X-4051 | 1 " |
9. VSWR Meter, Solid State | VS-411 | 1 " |
10. Waveguide Stands | X-5035 | 1 " |
11. Cooling Fan | .... | 1 " |
Slotted-Section with Probe-Carriage
The waveguide slotted line, comprise of an accurately machined section of waveguide in which a small longitudinal slot has been cut which is a basic means for monitoring wave-patterns inside the waveguide system. Such data may be transformed into impedance of the terminal load of unknown system of components, percent of transmitted power, degree of antenna-match and other characteristics of waveguide.
A precision built probe carriage has a centimeter-scale with a vernier reading of 0.1 mm least count and a dialgauge can be mounted easily if precise readings are required.
A precision built probe carriage has a centimeter-scale with a vernier reading of 0.1 mm least count and a dialgauge can be mounted easily if precise readings are required.
Model No. | L-6051 | S-6051 | C-6051 | J-6051 | X-6051 | KU-6051 | K-6051 | R-6051 |
Frequency | 1.7-2.6 | 2.6-3.95 | 3.95-5.85 | 5.85-8.2 | 8.2-12.4 | 12.4-18.0 | 18.0-26.5 | 26.5-40.0 |
Max. Residual VSWR | 1.01 | 1.01 | 1.01 | 1.01 | 1.01 | 1.01 | 1.01 | 1.01 |
Waveguide Type (WR-) | 430 | 284 | 187 | 137 | 90 | 62 | 42 | 28 |
Flange Type (UG-/U) | CPR-430 | 53 | 149A | 344 | 39 | 419 | 595 | 599 |
Length of Slotted | 40 | 30 | 20 | 15 | 15 | 15 | 12 | 10 |
Waveguide Conical
Model 5101 is a Conical Antenna with approx gain of 15 db. It has round waveguide on one end and conical body with round aperture on the other end.
A Circular to Rectangular Waveguide Transition (Model 9051) is required to connect this antenna with rectangular waveguide test-systems.
Microwave Lab Kit VX-2002
Product Brochure
Usage/Application | Laboratory |
Model Name/Number | VX 2002 |
Brand | VIDYUT |
Country of Origin | Made in India |
1. To study the Characteristics of Gunn Diode.2. o study Frequency, Guide Wavelength & free Space Wavelength.3. To measure the SWR & Reflection Coefficient.4. To measure Impedence of a load.
Tunable Detector Mount
Model 4151 A, B & C Coaxial Detector Mounts are coaxial untunable type fixed detector mounts for use with coaxial outputs. These are low SWR devices having flat frequency response and high sensitivity.
These consists of N (M) connector on input side and BNC (F) connector on Output side and a crystal diode with matching disc is mounted inside.
Other coaxial accessories available are:
1. Coaxial short, N OR SMA
2. Coaxial termination, N OR SMA
3. Coaxial variable attenuator
4. Coaxial tees ETC.