Series 5000 Fixed Attenuators are meant for inserting a known
attenuation in a waveguide system. These consists of a lossy-vane
inserted in a section of waveguide, flanged on both ends. These are
useful for isolation of waveguide circuits, padding and extending the
range of measuring equipments
Fixed attenuators are available for 3, 6,10 and 20 db attenuation
values, but any attenuation value between 1 and 30 db can be provided.
Please add the attenuation-value to the last digit of series 500 e.g.
3db attenuator as 5003 and 10 db attenuator as 5010.
|
|
Model No.
|
Waveguide Type
|
Frequency Range
(GHz)
|
Attenuation
(db)
|
Calibration
Accuracy(db)
|
Av. Power
(watts)
|
Max. VSWR
|
Max. Insertion
Loss(db)
|
Flange Type(UG-/U)
|
|
L-5000
|
WR-430
|
1.7-2.6
|
3,6,10
|
0.2
|
10
|
1.10
|
0.2
|
CPR-430
|
|
S-5000
|
WR-284
|
2.6-3.95
|
3,6,10
|
0.2
|
5
|
1.10
|
0.2
|
53
|
|
C-5000
|
WR-187
|
3.95-5.85
|
3,6,10
|
0.2
|
5
|
1.10
|
0.2
|
149A
|
|
J-5000
|
WR-137
|
5.85-8.2
|
3,6,10
|
0.2
|
3
|
1.10
|
0.2
|
344
|
|
X-5000
|
WR-90
|
8.2-12.4
|
3,6,10
|
0.2
|
2
|
1.10
|
0.2
|
39
|
|
Ku-5000
|
WR-62
|
12.4-18.0
|
3,6,10
|
0.2
|
1
|
1.15
|
0.3
|
419
|
|
K-5000
|
WR-42
|
18.0-26.5
|
3,6,10
|
0.25
|
0.5
|
1.15
|
0.3
|
595
|
|
R-5000
|
WR-28
|
26.5-40.0
|
3,6,10
|
0.3
|
0.5
|
1.15
|
0.4
|
599
|
|
 |